Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 7.387µH
Inductance - Connected In Series 29.55µH
Tolerance ±20%
Current Rating - Parallel 7.34A
Current Rating - Series 3.67A
Current Saturation - Parallel 13.3A
Current Saturation - Series 6.67A
DC Resistance (DCR) - Parallel 11.6mOhm
DC Resistance (DCR) - Series 46.5mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.492" L x 0.492" W (12.50mm x 12.50mm)
Height 0.315" (8.00mm)
DRQ127-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 91.72µH Inductance - Connected in Series 22.93µH Inductance - Connected in Parallel 39.1mOhm DC Resistance (DCR) - Parallel 4A Nonstandard, DRQ
View
DRQ125-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 89.44µH Inductance - Connected in Series 22.36µH Inductance - Connected in Parallel 39.6mOhm DC Resistance (DCR) - Parallel 3.7A Nonstandard, DRQ
View
DRQ125-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 189.9µH Inductance - Connected in Series 47.47µH Inductance - Connected in Parallel 74mOhm DC Resistance (DCR) - Parallel 2.71A Nonstandard, DRQ
View
DRQ125-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 21.1µH Inductance - Connected in Series 5.274µH Inductance - Connected in Parallel 10.5mOhm DC Resistance (DCR) - Parallel 7.18A Nonstandard, DRQ
View
DRQ125-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 12.34µH Inductance - Connected in Series 3.084µH Inductance - Connected in Parallel 6.3mOhm DC Resistance (DCR) - Parallel 9.26A Nonstandard, DRQ
View
DRQ74-471-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 1.861mH Inductance - Connected in Series 465.3µH Inductance - Connected in Parallel 1.74Ohm DC Resistance (DCR) - Parallel 400mA Nonstandard, DRQ
View
DRQ74-151-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 600µH Inductance - Connected in Series 150µH Inductance - Connected in Parallel 591mOhm DC Resistance (DCR) - Parallel 690mA Nonstandard, DRQ
View
DRQ127-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 19.36µH Inductance - Connected in Series 4.841µH Inductance - Connected in Parallel 9.17mOhm DC Resistance (DCR) - Parallel 8.25A Nonstandard, DRQ
View
DRQ127-2R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 8.108µH Inductance - Connected in Series 2.027µH Inductance - Connected in Parallel 3.73mOhm DC Resistance (DCR) - Parallel 12.5A Nonstandard, DRQ
View
DRQ73-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 405.6µH Inductance - Connected in Series 101.4µH Inductance - Connected in Parallel 527mOhm DC Resistance (DCR) - Parallel 730mA Nonstandard, DRQ
View
DRQ127-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 29.55µH Inductance - Connected in Series 7.387µH Inductance - Connected in Parallel 11.6mOhm DC Resistance (DCR) - Parallel 7.34A Nonstandard, DRQ
View
DRQ73-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 60.04µH Inductance - Connected in Series 15.01µH Inductance - Connected in Parallel 84.4mOhm DC Resistance (DCR) - Parallel 1.83A Nonstandard, DRQ
View