Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 22.36µH
Inductance - Connected In Series 89.44µH
Tolerance ±20%
Current Rating - Parallel 3.7A
Current Rating - Series 1.84A
Current Saturation - Parallel 4.71A
Current Saturation - Series 2.36A
DC Resistance (DCR) - Parallel 39.6mOhm
DC Resistance (DCR) - Series 159mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.492" L x 0.492" W (12.50mm x 12.50mm)
Height 0.236" (6.00mm)
DRQ125-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 410.8µH Inductance - Connected in Series 102.7µH Inductance - Connected in Parallel 170mOhm DC Resistance (DCR) - Parallel 1.78A Nonstandard, DRQ
View
DRQ125-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 26.35µH Inductance - Connected in Series 6.588µH Inductance - Connected in Parallel 12.3mOhm DC Resistance (DCR) - Parallel 6.64A Nonstandard, DRQ
View
DRQ73-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 60.04µH Inductance - Connected in Series 15.01µH Inductance - Connected in Parallel 84.4mOhm DC Resistance (DCR) - Parallel 1.83A Nonstandard, DRQ
View
DRQ127-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.02mH Inductance - Connected in Series 1.005mH Inductance - Connected in Parallel 1.66Ohm DC Resistance (DCR) - Parallel 610mA Nonstandard, DRQ
View
DRQ73-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 137.6µH Inductance - Connected in Series 34.41µH Inductance - Connected in Parallel 166mOhm DC Resistance (DCR) - Parallel 1.31A Nonstandard, DRQ
View
DRQ127-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 188.2µH Inductance - Connected in Series 47.05µH Inductance - Connected in Parallel 71.9mOhm DC Resistance (DCR) - Parallel 2.95A Nonstandard, DRQ
View
DRQ127-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 29.55µH Inductance - Connected in Series 7.387µH Inductance - Connected in Parallel 11.6mOhm DC Resistance (DCR) - Parallel 7.34A Nonstandard, DRQ
View
DRQ74-151-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 600µH Inductance - Connected in Series 150µH Inductance - Connected in Parallel 591mOhm DC Resistance (DCR) - Parallel 690mA Nonstandard, DRQ
View
DRQ74-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 406.4µH Inductance - Connected in Series 101.6µH Inductance - Connected in Parallel 383mOhm DC Resistance (DCR) - Parallel 860mA Nonstandard, DRQ
View
DRQ127-680-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 265.9µH Inductance - Connected in Series 66.48µH Inductance - Connected in Parallel 105mOhm DC Resistance (DCR) - Parallel 2.44A Nonstandard, DRQ
View
DRQ127-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.02mH Inductance - Connected in Series 1.005mH Inductance - Connected in Parallel 1.66Ohm DC Resistance (DCR) - Parallel 610mA Nonstandard, DRQ
View
DRQ74-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 198.6µH Inductance - Connected in Series 49.64µH Inductance - Connected in Parallel 216mOhm DC Resistance (DCR) - Parallel 1.15A Nonstandard, DRQ
View