Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 465.3µH
Inductance - Connected In Series 1.861mH
Tolerance ±20%
Current Rating - Parallel 400mA
Current Rating - Series 202mA
Current Saturation - Parallel 460mA
Current Saturation - Series 230mA
DC Resistance (DCR) - Parallel 1.74Ohm
DC Resistance (DCR) - Series 6.97Ohm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.299" L x 0.299" W (7.60mm x 7.60mm)
Height 0.175" (4.45mm)
DRQ125-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 12.34µH Inductance - Connected in Series 3.084µH Inductance - Connected in Parallel 6.3mOhm DC Resistance (DCR) - Parallel 9.26A Nonstandard, DRQ
View
DRQ73-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 17.69µH Inductance - Connected in Series 4.422µH Inductance - Connected in Parallel 29.7mOhm DC Resistance (DCR) - Parallel 3.09A Nonstandard, DRQ
View
DRQ74-151-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 600µH Inductance - Connected in Series 150µH Inductance - Connected in Parallel 591mOhm DC Resistance (DCR) - Parallel 690mA Nonstandard, DRQ
View
DRQ73-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 25.92µH Inductance - Connected in Series 6.48µH Inductance - Connected in Parallel 43.5mOhm DC Resistance (DCR) - Parallel 2.55A Nonstandard, DRQ
View
DRQ127-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 91.72µH Inductance - Connected in Series 22.93µH Inductance - Connected in Parallel 39.1mOhm DC Resistance (DCR) - Parallel 4A Nonstandard, DRQ
View
DRQ74-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 20.73µH Inductance - Connected in Series 5.182µH Inductance - Connected in Parallel 25.4mOhm DC Resistance (DCR) - Parallel 3.34A Nonstandard, DRQ
View
DRQ127-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 19.36µH Inductance - Connected in Series 4.841µH Inductance - Connected in Parallel 9.17mOhm DC Resistance (DCR) - Parallel 8.25A Nonstandard, DRQ
View
DRQ74-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 406.4µH Inductance - Connected in Series 101.6µH Inductance - Connected in Parallel 383mOhm DC Resistance (DCR) - Parallel 860mA Nonstandard, DRQ
View
DRQ127-221-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 886µH Inductance - Connected in Series 221.5µH Inductance - Connected in Parallel 376mOhm DC Resistance (DCR) - Parallel 1.29A Nonstandard, DRQ
View
DRQ127-8R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 35.44µH Inductance - Connected in Series 8.861µH Inductance - Connected in Parallel 15.7mOhm DC Resistance (DCR) - Parallel 6.32A Nonstandard, DRQ
View
DRQ125-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 410.8µH Inductance - Connected in Series 102.7µH Inductance - Connected in Parallel 170mOhm DC Resistance (DCR) - Parallel 1.78A Nonstandard, DRQ
View
DRQ127-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 11.32µH Inductance - Connected in Series 2.831µH Inductance - Connected in Parallel 5.67mOhm DC Resistance (DCR) - Parallel 10.4A Nonstandard, DRQ
View