Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 102.7µH
Inductance - Connected In Series 410.8µH
Tolerance ±20%
Current Rating - Parallel 1.78A
Current Rating - Series 892mA
Current Saturation - Parallel 2.2A
Current Saturation - Series 1.1A
DC Resistance (DCR) - Parallel 170mOhm
DC Resistance (DCR) - Series 682mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.492" L x 0.492" W (12.50mm x 12.50mm)
Height 0.236" (6.00mm)
DRQ125-221-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 867.2µH Inductance - Connected in Series 216.8µH Inductance - Connected in Parallel 384mOhm DC Resistance (DCR) - Parallel 1.19A Nonstandard, DRQ
View
DRQ74-151-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 600µH Inductance - Connected in Series 150µH Inductance - Connected in Parallel 591mOhm DC Resistance (DCR) - Parallel 690mA Nonstandard, DRQ
View
DRQ74-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 86.92µH Inductance - Connected in Series 21.73µH Inductance - Connected in Parallel 92.5mOhm DC Resistance (DCR) - Parallel 1.75A Nonstandard, DRQ
View
DRQ125-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 61.4µH Inductance - Connected in Series 15.35µH Inductance - Connected in Parallel 29.8mOhm DC Resistance (DCR) - Parallel 4.27A Nonstandard, DRQ
View
DRQ125-681-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 2.719mH Inductance - Connected in Series 679.8µH Inductance - Connected in Parallel 1.1Ohm DC Resistance (DCR) - Parallel 700mA Nonstandard, DRQ
View
DRQ125-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 12.34µH Inductance - Connected in Series 3.084µH Inductance - Connected in Parallel 6.3mOhm DC Resistance (DCR) - Parallel 9.26A Nonstandard, DRQ
View
DRQ74-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 20.73µH Inductance - Connected in Series 5.182µH Inductance - Connected in Parallel 25.4mOhm DC Resistance (DCR) - Parallel 3.34A Nonstandard, DRQ
View
DRQ127-2R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 8.108µH Inductance - Connected in Series 2.027µH Inductance - Connected in Parallel 3.73mOhm DC Resistance (DCR) - Parallel 12.5A Nonstandard, DRQ
View
DRQ127-100-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 41.88µH Inductance - Connected in Series 10.47µH Inductance - Connected in Parallel 17.2mOhm DC Resistance (DCR) - Parallel 6.04A Nonstandard, DRQ
View
DRQ127-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 19.36µH Inductance - Connected in Series 4.841µH Inductance - Connected in Parallel 9.17mOhm DC Resistance (DCR) - Parallel 8.25A Nonstandard, DRQ
View
DRQ127-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 56.36µH Inductance - Connected in Series 14.09µH Inductance - Connected in Parallel 24.7mOhm DC Resistance (DCR) - Parallel 5.03A Nonstandard, DRQ
View
DRQ73-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 137.6µH Inductance - Connected in Series 34.41µH Inductance - Connected in Parallel 166mOhm DC Resistance (DCR) - Parallel 1.31A Nonstandard, DRQ
View