Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 221.5µH
Inductance - Connected In Series 886µH
Tolerance ±20%
Current Rating - Parallel 1.29A
Current Rating - Series 645mA
Current Saturation - Parallel 2.43A
Current Saturation - Series 1.22A
DC Resistance (DCR) - Parallel 376mOhm
DC Resistance (DCR) - Series 1.5Ohm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.492" L x 0.492" W (12.50mm x 12.50mm)
Height 0.315" (8.00mm)
DRQ73-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 25.92µH Inductance - Connected in Series 6.48µH Inductance - Connected in Parallel 43.5mOhm DC Resistance (DCR) - Parallel 2.55A Nonstandard, DRQ
View
DRQ127-821-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 3.272mH Inductance - Connected in Series 818.1µH Inductance - Connected in Parallel 1.47Ohm DC Resistance (DCR) - Parallel 650mA Nonstandard, DRQ
View
DRQ125-680-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 271.6µH Inductance - Connected in Series 67.91µH Inductance - Connected in Parallel 101mOhm DC Resistance (DCR) - Parallel 2.22A Nonstandard, DRQ
View
DRQ74-471-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 1.861mH Inductance - Connected in Series 465.3µH Inductance - Connected in Parallel 1.74Ohm DC Resistance (DCR) - Parallel 400mA Nonstandard, DRQ
View
DRQ73-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 17.69µH Inductance - Connected in Series 4.422µH Inductance - Connected in Parallel 29.7mOhm DC Resistance (DCR) - Parallel 3.09A Nonstandard, DRQ
View
DRQ73-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 137.6µH Inductance - Connected in Series 34.41µH Inductance - Connected in Parallel 166mOhm DC Resistance (DCR) - Parallel 1.31A Nonstandard, DRQ
View
DRQ127-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 91.72µH Inductance - Connected in Series 22.93µH Inductance - Connected in Parallel 39.1mOhm DC Resistance (DCR) - Parallel 4A Nonstandard, DRQ
View
DRQ74-151-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 600µH Inductance - Connected in Series 150µH Inductance - Connected in Parallel 591mOhm DC Resistance (DCR) - Parallel 690mA Nonstandard, DRQ
View
DRQ74-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 20.73µH Inductance - Connected in Series 5.182µH Inductance - Connected in Parallel 25.4mOhm DC Resistance (DCR) - Parallel 3.34A Nonstandard, DRQ
View
DRQ127-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.02mH Inductance - Connected in Series 1.005mH Inductance - Connected in Parallel 1.66Ohm DC Resistance (DCR) - Parallel 610mA Nonstandard, DRQ
View
DRQ74-471-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 1.861mH Inductance - Connected in Series 465.3µH Inductance - Connected in Parallel 1.74Ohm DC Resistance (DCR) - Parallel 400mA Nonstandard, DRQ
View
DRQ127-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 29.55µH Inductance - Connected in Series 7.387µH Inductance - Connected in Parallel 11.6mOhm DC Resistance (DCR) - Parallel 7.34A Nonstandard, DRQ
View