Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 3.54µH
Inductance - Connected In Series 14.16µH
Tolerance ±20%
Current Rating - Parallel 3.31A
Current Rating - Series 1.66A
Current Saturation - Parallel 4.22A
Current Saturation - Series 2.11A
DC Resistance (DCR) - Parallel 25.9mOhm
DC Resistance (DCR) - Series 103.5mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.299" L x 0.299" W (7.60mm x 7.60mm)
Height 0.140" (3.55mm)
DRQ74-471-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 1.861mH Inductance - Connected in Series 465.3µH Inductance - Connected in Parallel 1.74Ohm DC Resistance (DCR) - Parallel 400mA Nonstandard, DRQ
View
DRQ73-100-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 41.2µH Inductance - Connected in Series 10.3µH Inductance - Connected in Parallel 65.6mOhm DC Resistance (DCR) - Parallel 2.08A Nonstandard, DRQ
View
DRQ127-1R0-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 3.284µH Inductance - Connected in Series 821nH Inductance - Connected in Parallel 2.61mOhm DC Resistance (DCR) - Parallel 15.5A Nonstandard, DRQ
View
DRQ73-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 60.04µH Inductance - Connected in Series 15.01µH Inductance - Connected in Parallel 84.4mOhm DC Resistance (DCR) - Parallel 1.83A Nonstandard, DRQ
View
DRQ74-151-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 600µH Inductance - Connected in Series 150µH Inductance - Connected in Parallel 591mOhm DC Resistance (DCR) - Parallel 690mA Nonstandard, DRQ
View
DRQ73-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 17.69µH Inductance - Connected in Series 4.422µH Inductance - Connected in Parallel 29.7mOhm DC Resistance (DCR) - Parallel 3.09A Nonstandard, DRQ
View
DRQ74-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 86.92µH Inductance - Connected in Series 21.73µH Inductance - Connected in Parallel 92.5mOhm DC Resistance (DCR) - Parallel 1.75A Nonstandard, DRQ
View
DRQ74-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 86.92µH Inductance - Connected in Series 21.73µH Inductance - Connected in Parallel 92.5mOhm DC Resistance (DCR) - Parallel 1.75A Nonstandard, DRQ
View
DRQ74-680-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 278.7µH Inductance - Connected in Series 69.67µH Inductance - Connected in Parallel 265mOhm DC Resistance (DCR) - Parallel 1.03A Nonstandard, DRQ
View
DRQ73-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 17.69µH Inductance - Connected in Series 4.422µH Inductance - Connected in Parallel 29.7mOhm DC Resistance (DCR) - Parallel 3.09A Nonstandard, DRQ
View
DRQ73-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 194.5µH Inductance - Connected in Series 48.62µH Inductance - Connected in Parallel 241mOhm DC Resistance (DCR) - Parallel 1.08A Nonstandard, DRQ
View
DRQ125-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 410.8µH Inductance - Connected in Series 102.7µH Inductance - Connected in Parallel 170mOhm DC Resistance (DCR) - Parallel 1.78A Nonstandard, DRQ
View